Ontario Drill Hole Database

GeologyOntario has moved and you should be redirected to the new GeologyOntario in 10 seconds.

Ministry of Energy, Northern Development and Mines
Permanent Link to this Record: Drill Hole Summary for 42J09SE0001

Drill Hole Summary for Assessment File 42J09SE0001

Company
Onexco Minerals Ltd
NTS
42I12NW, 42I12SW, 42J01NW, 42J02NE, 42J02NW, 42J07NE, 42J07SE, 42J08NE, 42J08NW, 42J08SW, 42J09SE
Township or Area
Acres, Garden, Gentles, Habel, Hambly, Lambert, Mahoney, McBrien, McCausland, McCuaig, Pickett, Rapley, West Of Gentles Area, Wright
Resident Geologist District
Timmins
Year Drilled
1982, 1983
Assessment File

Drill Hole Details

Hole Type
ENDM Hole ID
Company Hole ID
Township/Area
UTM Datum
UTM Zone
Easting
Northing
Dip (degrees)
Azimuth (degrees)
Overburden Depth
Length
Elements
Comments
Reverse Circulation (Sonic)
68449
ONEX-W83-01
West Of Gentles Area
NAD27
17
421573.81
5595285.13
-90
66.77
117.38
Graphical log. Sampling indicated. No results given. Additional holes indicated
Reverse Circulation (Sonic)
68450
ONEX-W83-02
Gentles
NAD27
17
423803.43
5595212.45
-90
49.7
102.29
Graphical log
Reverse Circulation (Sonic)
68451
ONEX-W83-03
West Of Gentles Area
NAD27
17
420640.35
5597051.7
-90
47.1
116.46
Graphical log. Sampling indicated. No results given
Reverse Circulation (Sonic)
68452
ONEX-W83-04
Gentles
NAD27
17
422308.83
5597540.7
-90
108.84
129.57
Graphical log.
Reverse Circulation (Sonic)
68453
ONEX-W83-05
Gentles
NAD27
17
422053.86
5599324.96
-90
54.12
71.65
Graphical log.
Reverse Circulation (Sonic)
68454
ONEX-W83-06
Gentles
NAD27
17
424346.14
5601125.88
-90
80.79
95.73
Graphical log. Sampling indicated. No results given
Reverse Circulation (Sonic)
68455
ONEX-W83-07
West Of Gentles Area
NAD27
17
419801.03
5600966.02
-90
44.82
89.63
Graphical log.
Reverse Circulation (Sonic)
68456
ONEX-W83-08
Gentles
NAD27
17
422876.66
5602389.08
-90
73.48
80.79
Graphical log.
Reverse Circulation (Sonic)
68457
ONEX-W83-09
West Of Gentles Area
NAD27
17
420182.73
5599795.19
-90
66.92
114.33
Graphical log. Sampling indicated. No results given
Reverse Circulation (Sonic)
68458
ONEX-W83-10
West Of Gentles Area
NAD27
17
419042.69
5598360.36
-90
76.52
106.4
Graphical log. Sampling indicated. No results given
Reverse Circulation (Sonic)
68459
ONEX-W83-11
West Of Gentles Area
NAD27
17
419277.82
5595968
-90
37.2
121.95
Graphical log. Sampling indicated. No results given
Reverse Circulation (Sonic)
68460
ONEX-W83-12
West Of Gentles Area
NAD27
17
420020.57
5597663.26
-90
66.46
121.19
Graphical log. Sampling indicated. No results given
Reverse Circulation (Sonic)
68461
ONEX-W83-13
Gentles
NAD27
17
423677.97
5593474.74
-90
79.27
120.73
Graphical log.
Reverse Circulation (Sonic)
68462
ONEX-W83-14
Gentles
NAD27
17
425327.5
5597250.71
-90
46.65
71.65
Graphical log.
Reverse Circulation (Sonic)
68463
ONEX-W83-15
Gentles
NAD27
17
432543.27
5602060.89
-90
69.21
111.28
Graphical log.
Reverse Circulation (Sonic)
68464
ONEX-W83-16
Gentles
NAD27
17
435958.31
5601295.44
-90
33.54
84.15
Graphical log.
Reverse Circulation (Sonic)
68465
ONEX-W83-17
Gentles
NAD27
17
436429.43
5602705.48
-90
54.57
67.07
Graphical log.
Reverse Circulation (Sonic)
68466
ONEX-W83-18
Pickett
NAD27
17
437903.32
5602867.43
-90
38.72
47.26
Graphical log.
Reverse Circulation (Sonic)
68467
ONEX-W83-19
Pickett
NAD27
17
438092.19
5600121.64
-90
41.01
42.68
Graphical log.
Reverse Circulation (Sonic)
68468
ONEX-W83-20
Gentles
NAD27
17
434075.47
5604062.3
-90
100.76
121.34
Graphical log.
Reverse Circulation (Sonic)
68469
ONEX-W83-21
Gentles
NAD27
17
436166.69
5598343.04
-90
51.68
62.5
Graphical log.
Reverse Circulation (Sonic)
68470
ONEX-W83-22
Gentles
NAD27
17
433994.12
5602077.68
-90
56.71
97.87
Graphical log. Sampling indicated. No results given
Reverse Circulation (Sonic)
68471
ONEX-W83-23
McCuaig
NAD27
17
436452.96
5609831.37
-90
60.52
93.87
Graphical log. Sampling indicated. No results given. This hole may have pyrope and diamond testing.
Reverse Circulation (Sonic)
68472
ONEX-W83-24
Gentles
NAD27
17
436445.33
5607446.43
-90
44.15
81.71
Graphical log. Sampling indicated. No results given
Reverse Circulation (Sonic)
68473
ONEX-W83-25
Gentles
NAD27
17
433517.62
5606378.05
-90
114.02
120.43
Graphical log.
Reverse Circulation (Sonic)
68474
ONEX-W83-26
Lambert
NAD27
17
414999.56
5588558.33
-90
47.87
106.71
Graphical log. Sampling indicated. No results given. There appears to be a misnumbered geophysical log for this hole, (geophysical logs may be misnumbered based on township location).
Reverse Circulation (Sonic)
68475
ONEX-W83-27
Mahoney
NAD27
17
408844.81
5584102.92
-90
80.64
131.1
Graphical log. (geophysical logs may be misnumbered based on township location)
Reverse Circulation (Sonic)
68476
ONEX-W83-28
Habel
NAD27
17
394439.76
5582804.32
-90
80.79
122.56
Graphical log. Sampling indicated. No results given. (geophysical logs may be misnumbered based on township location)
Reverse Circulation (Sonic)
68477
ONEX-82-1
Gentles
NAD27
17
434439.41
5601494.11
-90
52.74
Logs not available. Data obtained from maps. Probably reverse circulation drilling.
Reverse Circulation (Sonic)
68478
ONEX-82-2
Pickett
NAD27
17
439988.8
5603956.9
-90
84.76
Logs not available. Data obtained from maps. Probably reverse circulation drilling.
Reverse Circulation (Sonic)
68479
ONEX-82-3
Gentles
NAD27
17
436259.93
5609806.33
-90
80.79
Logs not available. Data obtained from maps. Probably reverse circulation drilling. Pyrope anomaly.
Reverse Circulation (Sonic)
68480
ONEX-82-4
Gentles
NAD27
17
431327.47
5604309.91
-90
89.02
Logs not available. Data obtained from maps. Probably reverse circulation drilling.
Reverse Circulation (Sonic)
68481
ONEX-82-5
Gentles
NAD27
17
434639.41
5602494.11
-90
98.78
Logs not available. Data obtained from maps. Probably reverse circulation drilling.
Reverse Circulation (Sonic)
68482
ONEX-82-6
Gentles
NAD27
17
437245.75
5604776.15
-90
79.88
Logs not available. Data obtained from maps. Probably reverse circulation drilling.
Reverse Circulation (Sonic)
68483
ONEX-82-7
Gentles
NAD27
17
427156.4
5599721.16
-90
Logs not available. Data obtained from maps. Probably reverse circulation drilling.
Reverse Circulation (Sonic)
68484
ONEX-82-8
West Of Gentles Area
NAD27
17
420575.11
5598320.75
-90
130.49
Logs not available. Data obtained from maps. Probably reverse circulation drilling.
Reverse Circulation (Sonic)
68485
ONEX-W83-23A
Gentles
NAD27
17
436452.96
5609836.37
-90
Logs not available. Data obtained from maps
Reverse Circulation (Sonic)
68486
ONEX-82-9
Rapley
NAD27
17
425531.42
5589151.37
-90
Logs not available. Data obtained from maps & report. Probably reverse circulation drilling.
Reverse Circulation (Sonic)
68487
ONEX-82-10
Acres
NAD27
17
402786.89
5564486.32
-90
Logs not available. Data obtained from maps & report. Probably reverse circulation drilling.
Reverse Circulation (Sonic)
68488
ONEX-82-11
Acres
NAD27
17
398391.22
5556142.21
-90
Logs not available. Data obtained from maps & report. Probably reverse circulation drilling.
Reverse Circulation (Sonic)
68489
ONEX-82-12
Wright
NAD27
17
386194.92
5554101.96
-90
118.9
Logs not available. Data obtained from maps & report. Probably reverse circulation drilling. Depth from core library
Reverse Circulation (Sonic)
68490
ONEX-82-13
Garden
NAD27
17
372022.88
5556436.69
-90
121.9
Logs not available. Data obtained from maps & report. Probably reverse circulation drilling. Depth from core library
Reverse Circulation (Sonic)
68491
ONEX-82-14
McBrien
NAD27
17
362463.04
5555230.52
-90
180.4
Logs not available. Data obtained from maps & report. Probably reverse circulation drilling. Depth from core library
Reverse Circulation (Sonic)
68492
ONEX-82-15
Hambly
NAD27
17
381853.11
5574135.47
-90
133.2
Logs not available. Data obtained from maps & report. Probably reverse circulation drilling. Depth from core library
Reverse Circulation (Sonic)
68493
ONEX-82-16
Hambly
NAD27
17
389090.62
5575505.23
-90
Logs not available. Data obtained from maps & report. Probably reverse circulation drilling
Reverse Circulation (Sonic)
68494
ONEX-82-17
Habel
NAD27
17
390259.8
5581661.45
-90
Logs not available. Data obtained from maps & report. Probably reverse circulation drilling.
Reverse Circulation (Sonic)
68495
ONEX-82-18
McCausland
NAD27
17
401436.23
5577659.76
-90
125
Logs not available. Data obtained from maps & report. Probably reverse circulation drilling. Depth from core library

Report an Error

We are continuously updating the Ontario Drill Hole Database. If you notice errors in the data please contact us.

Terms of Use

Please review our Terms of Use agreement for this data product.

Ministry Contact Information

Publication Sales
Ministry of Energy, Northern Development and Mines
933 Ramsey Lake Road, Level A3
Sudbury, Ontario P3E 6B5
Tel: 1-888-4155-9845, ext. 5691 (toll-free inside Canada and the United States)
Tel: (705) 670-5691 (local calls)
Fax: (705) 670-5770